Gas measurement of a container: what needs to be arranged before the doors open?

Home > Blog > Gas measurement of a container: what needs to be arranged before the doors open?
16 November 2026

From the outside, every sea container looks the same. Inside, things can be different: gases used to fight pests, or substances released by the cargo itself. Anyone who opens such a container without measuring runs a risk that cannot be seen and often cannot be smelled either.

In this blog you can read where these gases come from, what the law requires and how gas measurement and active ventilation of a container work in broad terms. You can also read how we arrange this for you at our container terminal in Doesburg.

In short

  • Import containers can contain harmful gases, due to fumigation against pests or due to off-gassing from products and packaging.
  • Under the Dutch Working Conditions Decree (Arbobesluit, article 3.5g), an employee may only enter a space with potentially dangerous gases once an inspection shows there is no danger.
  • A certified gas expert measures the container, records the result in a measurement report and advises on release or active ventilation.
  • At CTD, we arrange gas measurement and active ventilation at the terminal, always on the customer’s instructions.
  • Of the containers we had measured in 2025, almost one in five had to be actively ventilated.

Why a container can contain gases

The step-by-step plan from the Dutch Sector Institute for Transport and Logistics (STL) lists several causes:

  • Gas deliberately added to prevent or control pests (fumigation).
  • Gases that slow down spoilage or ripening of the cargo.
  • Substances that evaporate from products and packaging, such as glue and paint in furniture, shoes, toys or textiles.
  • Processes in the cargo itself, such as ripening fruit or rusting scrap metal that consumes oxygen.
  • Leaking packaging or residues from a previous cargo.

According to STL, most containers with gases come from Asia, Africa and South America. Even so, STL advises treating every import container as suspect, because most gases cannot be seen or smelled. There is a higher risk for, among other things, food and animal feed, furniture, textiles, shoes, toys and cargo with wooden pallets or dunnage.

We see at our own terminal that this is not an exception. Of all the containers we had measured in 2025, 19.76% had to be actively ventilated and measured again because the values at the first measurement were too high. So far in 2026, that share is 19.42%.


What the law requires

The duty to protect employees lies with the company whose employees open and unload the container. STL also stresses that working safely with gases concerns the entire logistics chain, from shipper to consignee.

The basis is article 3.5g of the Dutch Working Conditions Decree (Arbobesluit). In short: if you can suspect that hazardous substances are present in a space, an employee may only enter once an inspection shows there is no danger. Is there a danger? Then effective measures must be taken first. STL explains this in the tip card Additional measurements.

The law does not prescribe a fixed measurement method. For that, the sector drew up the step-by-step plan “Working safely with gases in sea containers”, including training requirements for gas experts (NTA 7496). The limit values per substance can be found in the limit value database of the SER (Social and Economic Council of the Netherlands), to which the step-by-step plan refers. STL is working on a renewed occupational health and safety catalogue; until then, the current version keeps its legal status.

How gas measurement and active ventilation of a container work

  1. Preliminary assessment
    Origin, cargo, packaging and transport documents give a first estimate of the risk. A deliberately fumigated container is listed in the transport documents under UN 3359.
  2. Measuring with the doors closed
    A gas expert measures the air inside the container, usually through the door seals, before anyone opens the doors.
  3. Assessing and advising
    The gas expert compares the results with the limit values and advises: release, actively ventilate first, or investigate further.
  4. Active ventilation
    If the values are too high, the container is actively ventilated. The doors stay closed and an installation with a filter cleans the air inside the container. This means the gas does not simply end up in the outside air.
  5. Measuring again
    Immediately after active ventilation, a new measurement follows. If the result is good, the container is released.

How long active ventilation takes depends on the type of gas, the concentration, the cargo and the weather. At CTD, this ranges from a few hours to sometimes a few days. For very high values or a deliberately fumigated container, STL advises calling in a specialised company (tip card Ventilation).

At CTD, we hold an environmental permit and two specialised external parties carry out the measurements and active ventilation. Containers that need to be measured are therefore also placed in a separate location on the terminal.


Measurement report and release

After the measurement, the gas expert draws up a measurement report with the results, a conclusion and advice. It includes, among other things, the container number, the substances measured, the equipment used, the comparison with the limit values and the advice on release.

The result applies to the moment of measurement. That is why the report often states a validity period. A common piece of advice is to open a released container within 24 hours, because the concentration can rise again later. For our deliveries, the customer opens the container themselves. In summer, a measurement may even be valid for only a few hours: heat and sun make the values rise faster.

Whoever opens the container decides on its release. As an example, STL mentions a written “safe to enter” declaration from the receiving company and advises keeping measurement data for ten years. According to STL, a gas-free certificate from the country of origin is for information only: it does not replace a measurement here.

At CTD, we receive the measurement report from the gas expert by email. Our driver takes a paper copy along and hands it to the customer on delivery.


Gas measurement during a customs inspection

If Dutch Customs wants to physically inspect a container (an FYCO), it first has to be safe to open. That is why Customs requires a gas measurement beforehand.

This inspection can take place at our terminal, which saves an extra trip to another location. Customs often also wants to inspect the container at the customer’s premises. In that case too, we arrange for a gas expert to come on site, on the customer’s instructions. The costs of the gas measurement are paid by the customer.


In practice at CTD

Containers are measured for gas and actively ventilated at our terminal every day. In summer there are more of them, because heat makes the values rise. Last summer, the values in a few containers were so high that the installation at our terminal could not bring them under control.

The customer’s supplier had used a new treatment for the wooden packaging, in too high a concentration. Those containers went back to Rotterdam and were ventilated there with heavier equipment.


How we arrange it at the terminal

At CTD, gas measurement is an additional service within our value added logistics and is always carried out on the customer’s instructions. If your container arrives at our terminal by inland waterway, this is how it works:

  1. Known in advance
    Before the container arrives, you let us know whether it needs to be measured for gas. You know what is in the container and which substances have been used, so that information always comes from you. You then give the order for the measurement. Containers that are measured are placed in a separate location on the terminal, as required by our environmental permit.
  2. Measuring on the unloading day
    We schedule the gas measurement based on the unloading date; it often takes place in the morning.
  3. Delivery the same day
    If the result is good, our container transport brings the container to your location the same day, together with the measurement report.
  4. Values too high?
    Then the container is actively ventilated and we reschedule the unloading date in consultation with you. If this is not possible at our terminal, the container goes to a location with heavier ventilation equipment. After a new measurement, the same process follows.

It is good to know that a measurement report is sometimes valid for only a few hours. We deliver within that period. If you want extra certainty, we can arrange an additional measurement on site on request. Whoever opens the container at the unloading location remains responsible for the release; the measurement report helps you substantiate that decision properly.

This way, your container arrives measured and, if necessary, ventilated, with the measurement report included. A container that may contain gas then does not have to wait on your own premises first. Request the gas measurement together with your booking, especially for cargo with a higher risk, such as food, furniture, textiles or cargo with wooden packaging. Contact us to discuss what is possible for your container flow. You can find answers about our other services in the frequently asked questions.


Frequently asked questions about container gas measurement

Is gas measurement of a container mandatory?

The law requires an inspection before employees enter a space with potentially dangerous gases (Dutch Working Conditions Decree, article 3.5g). Measuring is the usual way to demonstrate this. According to STL, a company with a regular container flow and a demonstrably negligible risk can work with random sampling.

Who is responsible for the gas measurement?

The company whose employees open and enter the container. That company may outsource the measurement or have it carried out by its own trained employees.

How long does active ventilation take?

That varies greatly per container and depends on the measured values, the type of gas, the cargo and the weather. At CTD, it ranges from a few hours to sometimes a few days. Ventilation is always followed by a new measurement.

How quickly should I open a released container?

A measurement applies to the moment it was taken. It is often advised to open a released container within 24 hours. In summer, a measurement may be valid for only a few hours due to the heat.

Does CTD arrange the gas measurement for a customs inspection?

Yes, on the customer’s instructions. This is possible for a physical inspection at our terminal as well as for an inspection at the customer’s location. The costs are paid by the customer.